Fotolia Laser Party

Specialist for Laser Photonics & Nanotechnology

  • Length measurement systems
  • Length and Angle Measurement Systems
  • Calibration systems
  • Vibration measurement systems

Laser interferometer

SP 5000 NG

  • flexible length measuring system of highest accuracy
  • easy handling and adjustment due to integrated beam direction detection
  • various optical reflectors can be used, e.g. triple mirror, spherical mirror, plane mirror reflector
  • permissible tilting of the measuring reflector up to ± 22.5°.
  • compact and robust design
  • sensor housing with splash water protection
  • design of the sensor head optionally in aluminum, stainless steel or invar
  • traceability to government standards
  • OEM versions, OEM software and vacuum version are possible
  • extended application range by optional interfaces
  • extensive trigger options

Long-Range laser interferometer

SP 15000 NG

SIOS long range laser interferometer
  • flexible length measuring system of highest accuracy
  • highly accurate length measurements over long distances
  • easy adjustment and handling
  • measuring ranges up to 80 m can be realized
  • compact design
  • extensive trigger options
  • open interfaces for OEM software under Windows and Linux

Differential laser interferometer

SP 5000 DI

SIOS differential laser interferometer
  • differential length or angle measurement of highest accuracy
  • minimization of environmental influences through differential measurement
  • thermally long-term stable sensor, temperature sensitivity < 20 nm/K
  • various optical reflectors can be used, e.g. spherical, plane mirror reflector
  • large tilt invariance of the measuring reflector
  • sensor head design in stainless steel as standard
  • beam distance: 21 mm
  • extensive trigger options
  • open interfaces for OEM software under Windows and Linux

Differential feedback laser interferometer

SP 5000 DI/F

SIOS differential feedback laser interferometer
  • differential length or angle measurement of highest accuracy
  • minimization of environmental influences through differential measurement
  • thermally ultra-stable sensor design, temperature sensitivity < 10 nm/K
  • various optical reflectors can be used, e.g. spherical, plane mirror reflector
  • large tilt invariance of the measuring reflector
  • compact and robust design
  • sensor head design in stainless steel as standard
  • Beam distance: 14 mm
  • OEM versions, OEM software and vacuum version are possible
  • can be used as a feedback system with optional interfaces
  • extensive trigger options

Double beam laser interferometer

SP 5000 DS

SIOS double beam laser interferometer
  • flexible length measuring system of highest accuracy
  • angle detection with highest accuracy
  • easy adjustment and handling
  • various optical reflectors can be used, e.g. spherical, plane mirror reflector
  • permissible tilting of the measuring reflector up to ± 12.5° 
  • compact design
  • sensor head is available in aluminum, stainless steel or invar
  • Beam distance: 12 mm standard, others on request
  • OEM versions, OEM software and vacuum version are possible
  • extensive trigger options

Triple beam laser interferometer

SP 5000 TR

SIOS triple beam laser interferometer
  • flexible length measuring system of highest accuracy
  • easy handling and adjustment due to integrated beam direction detection
  • various optical reflectors can be used, e.g. spherical, plane mirror reflector
  • permissible tilting of the measuring reflector up to ± 12.5°
  • compact design
  • design of the sensor head optionally in aluminum, stainless steel or invar
  • beam distance: 12 mm
  • OEM versions, OEM software and vacuum version are possible
  • beam deflection with an optionally available adjustable deflection mirror
  • extended range of applications through optional interfaces
  • extensive trigger options
  • calibration software according to the currently valid standards

Differential laser interferometer

SP 5000 DI

SIOS differential laser interferometer
  • differential length or angle measurement of highest accuracy
  • minimization of environmental influences through differential measurement
  • thermally long-term stable sensor, temperature sensitivity < 20 nm/K
  • various optical reflectors can be used, e.g. spherical, plane mirror reflector
  • large tilt invariance of the measuring reflector
  • sensor head design in stainless steel as standard
  • beam distance: 21 mm
  • extensive trigger options
  • open interfaces for OEM software under Windows and Linux

Calibration laser interferometer

SP 15000 C5

  • flexible length measuring system of highest accuracy
  • highly accurate length measurements over long distances
  • synchronous, continuous and, in conjunction with an optional roll angle sensor, 6 DoF measurements of length, pitch and yaw angles, and straightness
  • easy handling and adjustment due to integrated beam direction detection
  • large tilt invariance of the measuring reflector
  • beam distance: 50 mm
  • horizontal and vertical straightness component measurable by swiveling optics
  • extensive trigger options
  • open interfaces for OEM software under Windows and Linux
  • calibration software according to the currently valid standards

Vibrometer with fixed focal length

LSV 120 NG

SIOS laser vibrometer fixed focus lens
  • High-precision, non-contact vibration and length measurement
  • easy adjustment and handling
  • compact device with case for mobile use
  • the measuring system with a fixed focal length
  • fixed working distance customized 30 … 70 mm, 240 mm, 480 mm,
  • laser spot diameter 12 … 30 µm, 100 µm, 200 µm
  • FFT software for spectral analysis
  • extensive trigger options
  • open interfaces for OEM software under Windows and Linux

Vibrometer with exchangeable lens attachment

LSV 120 NG/L

SIOS laser vibrometer exchangeable lens
  • high-resolution vibration measurements and length measurements
  • frequency range from 0 Hz to 5 MHz
  • easy adjustment and handling
  • compact and robust design
  • the measuring system with interchangeable selectable focal lengths
  • lens accessible from the outside, quick-change mechanism without tools
  • laser spot diameter 12 … 30 µm, 100 µm, 200 µm
  • FFT software for spectral analysis
  • extensive trigger options
  • open interfaces for OEM software under Windows and Linux

Vibrometer with variable focal length

LSV 2500 NG

  • high-precision, non-contact vibration and length measurement
  • frequency range from 0 Hz to 5 MHz
  • easy adjustment and handling
  • compact device with case for mobile use
  • extensive trigger options
  • infinitely adjustable working distance in the range 240 mm to 2500 mm
  • FFT software for spectral analysis
  • open interfaces for OEM software under Windows and Linux

Nano Vibration Analyzer

NA

SIOS Nano vibration analyzer
  • high-precision, non-contact vibration measurement on micro-objects
  • easy adjustment and handling
  • extensive trigger options
  • X-Y table 50 mm x 50 mm, other options on request
  • Microscope objective 10x, 20x, 50x
  • Spot diameter 2 µm – 10 µm, (depending on objective)
  • OEM use of the vibrometer unit is possible
  • open interfaces for OEM software under Windows and Linux
  • FFT software for spectral analysis